Mendip Concrete Interlocking Tile

A double-pantile profile with elegant flowing lines, providing instant visual appeal.

Advantages
  • Versatile roof application well suited to most architectural styles
  • Enhanced strength due to the Double pantile design
  • A large choice of aesthetic colours and finishes including Standard Through Colour, Antique and Marley M22-coated premier concrete roof tile finish.

Click on a colour to view a larger version

A double pantile design with elegant flowing lines, instant visual appeal and exceptional strength the Marley Mendip concrete interlocking tile offers a stylish range of colours, and is a popular choice with discerning specifiers and builders alike.

Size of Tile

420 x 332 mm

Minimum Pitch

17,5ᴼ (100mm headlap)
26ᴼ (75mm headlap)

Maximum Pitch

45ᴼ (Above maximum pitch consult Marley Roofing)

Minimum Headlap

75mm (for pitch of 26ᴼ and above)
100mm (for pitches of 17,5ᴼ to 26ᴼ)

Maximum Gauge

320mm (100mm headlap and at pitches between 17,5ᴼ and 26ᴼ)
345mm (75mm headlap and at pitches of 26ᴼ and above)

Cover Width

300mm (nominal at lock mid shuffle position)

Covering Capacity

10,42 tiles/m² (net) at 100mm headlap
9,66 tiles/m² (net) at 75mm headlap

Weight of Tiling

+ - 46,9 kg/m²at 100mm headlap
+ - 43,5 kg/m² at 75mm headlap

Battens Required

3,13 lin.m/m² at 100mm headlap
2,9 lin.m/m² at 75mm headlap

Batten Size Recommended

38 x 38mm for rafters/supports not exceeding 760mm centres
38 x 50mm (batten fixed flat) for rafters/supports not exceeding 900mm centres
38 x 50mm (batten on edge) for rafters/supports not exceeding 1 000mm centres

Note: Above 760mm the rafter spacing can be increased only with engineer-designed trusses and with 38 x 50mm batten of the correct grade. All structural timber must comply with S.A National Standards.

Tile Nails

75mm Corrosion-resistant tile fixing nails

Hanging length

390mm (nominal)




Additional Notes

Marley Undertile Membrane or Radiant Barrier is recommended at all pitches in exposed and coastal areas.

The minimum pitch and minimum headlap must not be reduced under any circumstance. It is always better to raise the safety factor of the roof by adding a full course of tiles and increasing the tile headlap evenly on the rafter length.

In exposed areas the tile headlap may be increased, but greater lap is not as effective as a steeper pitch.

Due to natural variations in the raw materials and the occasional occurrence of efflorescence on concrete products, absolute colour uniformity on the roof cannot be guaranteed with Standard Through colour tiles.

All tiling and fixing to comply with SANS 10062 and 10400L code of practice.

Here at Marley Roofing, we are always on hand to offer practical and experienced support